| Power Supply | 100 ~ 240 V AC 50/60 Hz |
| Power Consumption | Approx. 3.5 VA (240 V AC) |
| Voltage for Sensor | 12 V DC ± 10 % 80 mA |
| Measurement Accuracy | | • Mode F1, F4, F10, F11, F12, F13: FS ± 0.05rdg ± 1 dig | | • Mode F2, F3, F5, F6: FS ± 0.01 %rdg ± 1 dig |
|
| Measurement Range | | • Mode F1, F10, F11, F12, F13: 0.0005 Hz ~ 50 Hz | | • Mode F3, F4: 0.02 s ~ 3.200 s | | • Mode F2, F5, F6: 0.01 s ~ 3.200 s | | • Mode F7, F8, F9: 0 ~ 4 x 109 Count |
|
| Input Signal | | Non-Contact Input: | | Max. 50 Hz (ON/OFF width for each above 10 ) | | (ON voltage: 4.5 V ~ 24 V, OFF voltage: 0 ~ 1.0 V) | | Contact Input: | | Max. 50 KHz (ON/OFF width for each above 8.3 ms) | | (12 V DC, able to switch the current of 2 mA sufficiently) |
|
| Max. Displayable Digits | 5 digits (-19999 ~ 99999) |
| Display Method | 7 Segment |
| Display Cycle | | 0.05/0.5/1/2/8sec | | (each setting for each bank/batch setting selection function) |
|
| Hysteresis | | 0 ~ 9999 (each setting for each bank/batch setting | | selection function, applicable only for output type) |
|
| Functions | | • Auto Zero Time Setting Function | | • Display Cycle Setting Function | | • Time Unit Selection Function | | (each setting for each bank/batch setting selection function) | | • Parameter Lock Function | | • 4 Steps Bank Setting Function | | • Remote/Local Conversion Function | | (applicable only for communication output type) | | • Current Output Range Selection Function | | (applicable only for current output type) | | • Max. Min. Peak Value 10 Steps Memory Function | | (Max.: 4 steps save, Average Value Save | | Min.: 4 steps save, Average Value Save) | | • Start Compensation Timer Function | | • Electricity Failure Compensation (applicable only for F9) | | • Comparative Output Function (HH, H, GO, L, LL) |
|
| Output | Output Types | | • Transistor Output (NPN Open Collector Output): | | Comparative, Alarm Output | | • Relay Output (HH, H, GO, L, LL) | | • PV Transfer Output (4 ~ 20 mA DC): Displayed Value Output | | • RS485 Communication Output (32 channels): Displayed | | Value Output, PC Setting Function (See the Output Specification) | | • BCD Dynamic Displayed Value Output Function |
|
Relay (main) | 277 V AC 3 A, 30 V DC 3 A MAX. |
Non-Contact (main) | NPN Open Collector 12 ~ 24 V DC 30 mA MAX. |
| BCD | NPN Open Collector 12 ~ 24 V DC 30 mA MAX. |
| Current | 4 ~ 20 mA DC Indicated Value(PV) Output, Resistive Load : below 600 Ω |
| Current Input | 4 ~ 20 mA DC Input |
| RS-485 Communication | 32 channels, two-way communication is possible |
| Memory | Non-volatile Memory (10 years) |
| Insulation Resistance | | Above 10 MΩ (at 500 V DC mega) Between electrically | | chargeable part and non-electrically chargeable part |
|
| Noise Immunity | By noise simulator, square-shaped wave noise (pulse width 1µs) ±2000 V |
Life Expentancy | Mechanical | | Above 100 thousand times | | (250 V AC 3 A, switching: 20 times/1 minute) |
|
| Electrical | Above 5 million times (switching: 180 times/1 minute) |
| Dielectric Strength | | 2000 V AC 60 Hz for 1 minute | | (between AC power terminal and case, | | between AC terminal and measurement input terminal) |
|
Vibration Resistance | Durability | | 10 ~ 55 Hz double amplitude width 0.75 mm | | in each X Y Z direction for 2 hours |
|
| Malfunction | | 10 ~ 55 Hz double amplitude width 0. 5 mm | | in each X Y Z direction for 10 minutes |
|
Shock Resistance | Durability | 300 m/s² (approx. 30G) in each X Y Z direction for 3times |
| Malfunction | 100 m/s² (approx. 10G) in each X Y Z direction for 3times |
Operating Ambient Temperature | -10 ~ +50 °C (without condensation) |
| Storage Temperature | -20 ~ +60 °C (without condensation) |
Operating Ambient Humidity | 35 ~ 85 % RH |
| Weight | Approx. 135 g |